Product Details:
|
| Rated Power: | 200 KVA / 160 KW | Voltage And Frequency: | 400/230 V, 50 Hz |
|---|---|---|---|
| Hazardous Area Rating: | ATEX Zone 2, IIA/IIB, T3 | Transfer Switch: | Integrated ATS With Mechanical And Electrical Interlock |
| Enclosure Protection: | IP55 Silent Weatherproof Canopy | Noise Level: | About 76 DB(A) At 7 M |
| Fuel Tank: | 400 L Base Tank | Control Interface: | Auto Start Module, Remote Alarm Contacts, Exercise Timer |
| Highlight: | gas compressor station backup,ATEX Zone 2 200KVA genset,ATS explosion proof power |
||
Gas compressor stations need a backup source that can take over the load of lubricating oil pumps, cooling fans, fuel gas heaters, instrument air and the station control system when the utility feed drops, and that backup source has to live inside an area where gas may be present. This 200 kVA explosion proof diesel generator set is configured for that duty, with an integrated automatic transfer switch so the station control system can call for power and receive it without a manual start at the panel.
The design assumes that the set will run unattended for long periods and that the operator will be watching it from a control room rather than standing beside it. Engine protection, generator protection, fuel level alarms, battery charger status and an automatic exercise schedule are all available as dry contacts, so station telemetry can treat the generator like any other intelligent field device. Every hot surface, cable entry and control component is protected for ATEX Zone 2 operation, which means the set can be installed beside the compressor building instead of behind a remote blast wall.
Key Features| Parameter | Specification |
|---|---|
| Rated power | 200 kVA / 160 kW at 0.8 power factor |
| Rated voltage and frequency | 400 / 230 V, 50 Hz, three phase four wire |
| Engine configuration | Water cooled six cylinder diesel, explosion proof modification |
| Rated speed | 1500 rpm, direct coupled brushless alternator |
| Hazardous area rating | ATEX Zone 2, gas group IIA / IIB, temperature class T3 |
| Transfer switch | Integrated ATS, mechanically and electrically interlocked |
| Enclosure protection | IP55 silent weatherproof canopy |
| Noise level | Approximately 76 dB(A) at 7 m |
| Fuel tank capacity | 400 L base tank, approximately 9 hours at 75 percent load |
| Control interface | Auto start module with remote alarm dry contacts and exercise timer |
The set is installed at gas compressor stations, city gate metering stations, gas storage facilities, LNG regasification support areas and associated pipeline control buildings. It also serves produced water pump stations and oil gathering facilities that share the same hazardous area classification. In stations without a permanent operator, the automatic transfer and remote alarm package turns the generator into part of the station telemetry system, so the control centre learns about a failed start or low fuel level before the process is affected.
Packaging & Quality AssuranceBefore dispatch the set runs a full load bank test at 25, 50, 75 and 100 percent load, an automatic transfer sequence test with simulated mains failure, protection trip simulation and noise verification. The test report, ATEX documentation, as built drawings and manual are supplied with each unit. The generator is protected with a shrink wrapped cover, fixed on a steel skid base and shipped in a seaworthy container, with lifting points and transport markings prepared according to the buyer delivery plan.