Product Details:
|
| Rated Power: | 500 KVA / 400 KW | Voltage And Frequency: | 400/230 V, 50 Hz |
|---|---|---|---|
| Hazardous Area Rating: | ATEX Zone 2, IIA/IIB, T3 | Container Shell: | 20 Foot ISO Container, IP55 Acoustic Enclosure |
| Noise Level: | About 78 DB(A) At 7 M | Fuel Tank: | 1000 L Bunded Internal Tank |
| Control System: | Explosion Proof Panel, Auto Start, Remote Alarm Contacts | Alternator: | Brushless, Class H Insulation |
| Highlight: | ATEX Zone 2 refinery generator,containerized 500KVA explosion proof,oil gas plant backup power |
||
Refineries, gas processing trains and product terminals cannot simply move their critical loads into a safe area when they need standby power inside the plant. This 500 kVA containerised explosion proof generator set is designed for that exact constraint: a complete ATEX Zone 2 power plant with 400 kW of usable output, packaged inside a steel container that can be lifted onto a foundation inside the classified zone and connected to the plant distribution board without any additional civil work or shelter.
The container shell carries the acoustic lining, the fire detection, the lighting, the fuel tank and the cable entries, so the whole assembly is delivered as one certified package instead of a set of loose components that would each need separate hazardous area assessment. For oil and gas operators, that packaging is what makes a large backup source practical: the unit can be dropped in during a turnaround, commissioned from the plant control room through remote alarm contacts, and removed again when the maintenance window closes.
Key Features| Parameter | Specification |
|---|---|
| Rated power | 500 kVA / 400 kW at 0.8 power factor |
| Rated voltage and frequency | 400 / 230 V, 50 Hz, three phase four wire |
| Engine configuration | Water cooled six cylinder turbocharged diesel, explosion proof modification |
| Rated speed | 1500 rpm, direct coupled brushless alternator |
| Hazardous area rating | ATEX Zone 2, gas group IIA / IIB, temperature class T3 |
| Container shell | 20 foot ISO container, IP55 acoustic enclosure |
| Noise level | Approximately 78 dB(A) at 7 m at container wall |
| Fuel tank capacity | 1000 L bunded internal tank, approximately 8 hours at full load |
| Control system | Explosion proof panel with auto start, remote alarm contacts, load sharing ready |
| Alternator insulation | Class H insulation, low reactance winding |
Typical installations include crude unit and hydrotreater substations, natural gas processing trains, LPG loading terminals, produced water treatment plants, sulphur recovery units and refinery utility buildings. The set also works as a mobile source during plant turnarounds, when temporary power is needed for welding receptacles, scaffold lighting and commissioning loads inside the classified area. In offshore support bases it provides back up for workshops and warehousing that sit inside the Zone 2 boundary of the terminal.
Packaging & Quality AssuranceThe unit runs a full load bank test covering 25, 50, 75 and 100 percent load steps together with transient response, protection simulation, fuel system pressure test and container weather sealing verification. Test reports, ATEX certificates, as built drawings and the operation manual accompany the shipment. The container is sealed with a marine grade protective cover, lashed on a flat rack or loaded into a break bulk vessel, and the lifting and transport markings follow the plan agreed with the buyer before dispatch.