Product Details:
|
| Rated Power: | 80 KVA / 64 KW | Voltage And Frequency: | 400/230 V, 50 Hz |
|---|---|---|---|
| Hazardous Area Rating: | ATEX Zone 2, IIA/IIB, T3 | Enclosure Protection: | IP55 Silent Canopy |
| Noise Level: | About 72 DB(A) At 7 M | Lifting Frame: | DNV 2.7-1 Four Point Certified Frame |
| Fuel Tank: | 200 L Base Tank | Alternator: | Brushless, Class H Insulation |
| Highlight: | ATEX Zone 2 explosion proof certified,DNV 2.7-1 offshore lifting frame,T3 silent canopy rig power |
||
This 80 kVA explosion proof diesel generator set is engineered for continuous duty inside ATEX Zone 2 hazardous areas, where a single ignition source can turn an ordinary power failure into a catastrophic event. Every electrical component on the set is selected, modified and documented for operation in a flammable gas atmosphere, so plant operators can place prime power exactly where the process demand is, instead of routing long temporary cables from a safe zone.
The complete package is built on a water-cooled four-stroke diesel engine with an integrated alternator, mounted on a DNV 2.7-1 certified lifting frame. The frame is proof loaded and marked for offshore crane handling, which lets the same unit serve a refinery laydown yard, an offshore platform deck and a drilling rig skid without any additional certification work. A silent weatherproof canopy keeps surface temperatures and noise inside the limits that hazardous area supervisors expect.
Key Features| Parameter | Specification |
|---|---|
| Rated power | 80 kVA / 64 kW at 0.8 power factor |
| Rated voltage and frequency | 400 / 230 V, 50 Hz, three phase four wire |
| Engine | Water cooled four-stroke diesel, explosion proof modification |
| Rated speed | 1500 rpm, direct coupled brushless alternator |
| Hazardous area rating | ATEX Zone 2, gas group IIA / IIB, temperature class T3 |
| Enclosure protection | IP55 weatherproof silent canopy |
| Noise level | Approximately 72 dB(A) at 7 m |
| Fuel tank capacity | 200 L base tank, approximately 10 hours at 75 percent load |
| Lifting arrangement | DNV 2.7-1 certified four-point offshore lifting frame |
| Alternator insulation | Class H insulation, IP23 winding protection |
The set is typically deployed as prime or standby power for offshore platform accommodation modules, drilling rig control rooms, wellhead skids, refinery loading terminals and pipeline compressor stations. Because the package carries both the ATEX Zone 2 marking and the DNV 2.7-1 lifting certification, procurement teams can release one unit for several sites and move it with a standard offshore crane rather than ordering separate safe area and hazardous area equipment. Typical loads include motor control centres, lighting and instrument circuits, communication racks, hydraulic power units and small process pumps.
Packaging & Quality AssuranceEach set is tested at the factory for load acceptance, voltage and frequency regulation, insulation resistance, protection function simulation and noise measurement, and the results are supplied with the unit. Certification documents, wiring diagrams and the operation and maintenance manual travel with the shipment. The generator is protected with a shrink wrapped canopy cover, anchored on a steel skid and shipped in a seaworthy container or on a flat rack, depending on the destination and the lifting plan agreed with the buyer.