logo
Home ProductsATEX Zone 2 Equipment

200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame

Certification
China Qingdao Kingway Industry Co., Ltd. certification
China Qingdao Kingway Industry Co., Ltd. certification
I'm Online Chat Now

200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame

200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame
200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame 200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame 200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame 200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame 200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame 200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame

Large Image :  200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame

Product Details:
Place of Origin: CHINA
Brand Name: Kingway Power
Certification: ATEX, DNV,BV,ROHS,CE
Model Number: EADG180-EX
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Price: 280800.00 USD-295800.00 USD
Packaging Details: DNV LIFTING FRAME, WOODEN CARTON
Delivery Time: 12-14 WEEKS
Payment Terms: L/C,T/T
Supply Ability: 200 UNITS PER YEAR

200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame

Description
Product: ATEX Certified DNV Lifting Frame Zone 2 Generator Set Brand Name: Kingway Power
Hazardous Area: Zone 2 Temperature Standards: T3
Certification: CE, ROHS,ATEX,BV,DNV Explosion Proof Mark: Zone 2 II 3G IIB T3 Gc
Color: Customized Warranty: 14 Months/ 2000 Working Hours
Delivery Time: 12-14 Weeks Lifting Frame: DNV Standards

200kVA ATEX Zone 2 Diesel Generator, Temperature Class T3, Mounted in DNV 2.7-1 Lifting Crash Frame

Our 200kVA ATEX Zone 2 Diesel Generator sets are engineered for hazardous locations, meeting strict Temperature Class T3 explosion-proof standards. Housed in a DNV 2.7-1 certified lifting crash frame, each heavy-duty offshore genset provides reliable, continuous standby or prime power for demanding oil and gas applications. Utilizing advanced emission control technology, Kingway diesel engines deliver optimized performance under extreme industrial conditions, ensuring maximum operational safety and stability. From large-scale distributed power stations to autonomous micro-grid solutions, Kingway power systems integrate precision electronic governors, robust cooling architectures, and intelligent remote-monitoring systems. Every unit is custom-calibrated to match specific environmental regulations, significantly reducing fuel costs and emissions while maximizing long-term return on investment.

Technical Specifications


ATEX Certified Zone 2 Ex proof Generator Set Specification
Model EADG200-EX
Prime Power 200KVA / 160KW
Frequency 50HZ
Voltage 400V
Certificate CE, ROHS,ATEX,BV,DNV 
IP Grade IP55
Category 3G
Conversion Zone 2 II 3G IIB T3 Gc
Directive 2014/34/EU-ATEX
Standards EN 60079 series / EN 1834 series / EN 1755
Lifting Frame DNV Standards 2.7-1
Generator IP Grade IP55
Enclosure Box IP65
Controller ComAp Mrs16
Ambient temp -25℃~ +60℃
Starting Method Electric Start, Spring Start, Pneumatic Start,Hydraulic Start

Why Choose Our Explosion-Proof Power Systems?

  • ATEX & IECEx Compliance: Fully certified Zone 2 protection with advanced thermal management meeting strict Temperature Class T3 standards.

  • DNV Standard Engineering: Integrated heavy-duty crash frames designed and built to DNV 2.7-1 offshore container lifting specifications.

  • Dual-Start Reliability: Equipped with synchronized electric and hydraulic starting systems to ensure fail-safe operation in hazardous environments.

  • High ROI & Full-Lifecycle Support: Optimized fuel efficiency combined with robust architecture ensures rapid project payback, complemented by 24/7 remote diagnostics.

Primary Applications

  • Environmental: Waste-to-energy projects at sewage treatment plants and landfills.
  • Agriculture: Large-scale livestock farms utilizing manure-based biogas systems.
  • Oil & Gas: Flared gas recovery and on-site power generation for drilling operations.

Frequently Asked Questions (FAQ)

Q1: How do I choose the correct generator for my gas source?

A: Gas composition and pressure are critical. Please provide a gas analysis report (including H2S content), and our engineering team will suggest the optimal model.

Q2: Can the generator operate in extreme temperatures?

A: Yes, we provide custom cooling systems, including specialized radiators or heat exchangers, for operational environments ranging from -40°C to +50°C.

Q3: How often is maintenance required?

A: Maintenance cycles depend on gas quality. We provide a tailored maintenance schedule and digital monitoring tools to track performance and predict service intervals.

Contact Details
Qingdao Kingway Industry Co., Ltd.

Contact Person: Mr. Bruce Jia

Tel: +8618653247836

Fax: 86-532-55718566

Send your inquiry directly to us (0 / 3000)