logo
Home ProductsResistive Load Bank

High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps

Certification
China Qingdao Kingway Industry Co., Ltd. certification
China Qingdao Kingway Industry Co., Ltd. certification
I'm Online Chat Now

High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps

High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps
High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps

Large Image :  High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps

Product Details:
Place of Origin: China
Brand Name: Kingway
Certification: CE/ISO
Model Number: KL500
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: USD9900-15000/Unit
Packaging Details: Plywood Cases
Delivery Time: 60 days
Payment Terms: L/C, T/T
Supply Ability: 100 Units per 60 days

High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps

Description
Highlight:

portable resistive load bank

,

adjustable step load bank

,

high-precision resistive load

Product Description

The 500KW 400V Resistive Load Bank is a high-capacity, heavy-duty testing system engineered to simulate medium-to-large electrical loads safely and accurately. Designed for 3-phase industrial power systems, it operates at a unity power factor (PF=1.0) to provide a purely resistive load, efficiently converting massive amounts of electrical energy into heat via specialized high-temperature alloy resistors.

Due to its high power rating, this unit features a robust, high-volume forced-air cooling system to ensure rapid heat dissipation and continuous, stable operation under full capacity. Often enclosed in a weather-resistant casing or skid-mounted frame, it is built to withstand demanding industrial environments. With granular load-stepping controls and advanced safety interlocks, the 500KW load bank is an indispensable asset for verifying the performance, reliability, and thermal endurance of large-scale generators, data center UPS systems, and marine power grids.

 

Technical Parameters

Parameter

Specification

Rated Power 500 KW
Rated Voltage 400V AC (3-Phase, 4-Wire)
Operating Frequency 50 Hz / 60 Hz
Load Type Purely Resistive
Power Factor (PF) 1.0
Load Step Resolution 10kW, 20kW, 20kW, 50kW, 100kW, 100kW, 200kW
Resistor Material High-temperature alloy (low temperature coefficient)
Cooling Method Forced Air Cooling (Multiple high-volume axial fans)
Control Mode Local push-button panel / Optional PLC & PC interface
Data Monitoring Digital multi-meter (Voltage, Current, Active Power, Frequency)
Enclosure Protection IP54 (Suitable for outdoor use)
Safety Protections Over-temperature, Fan failure interlock, Short-circuit, Over-voltage
Mobility Skid-mounted frame with lifting eyes and forklift pockets

 

 

Advantages

  • High-Capacity Stability: Utilizes premium alloy resistor tubes that do not produce "red heat" and maintain strict resistance values even at peak temperatures, ensuring load accuracy without fluctuation.
  • Intelligent & Granular Control: The load is divided into distinct, manageable steps (down to 10kW increments), allowing operators to test power sources at exact percentages (e.g., 25%, 50%, 75%, 100% load).
  • Fail-Safe Protection System: Equipped with an automated shutdown matrix. If the system detects a cooling fan failure, internal over-temperature, or a short circuit, it instantly drops the electrical load and triggers visual/audible alarms.
  • Heavy-Duty Weatherproofing: Housed in an IP54-rated, anti-corrosion steel enclosure, protecting the internal components from dust and moisture for reliable outdoor deployment.
  • Optimized Cooling Dynamics: Features a bottom-inlet to top-exhaust (or horizontal) airflow design, utilizing industrial-grade fans to rapidly expel heat and prevent thermal bottlenecks during extended test runs.

Applications

  • Data Center Commissioning: Essential for full-scale stress testing of critical power infrastructure, including large UPS modules, power distribution units (PDUs), and backup generators before servers are brought online.
  • Large Generator Maintenance: Used to conduct routine compliance testing and prevent "wet stacking" in medium-to-large standby diesel generators by forcing the engine to run at its optimal high temperature.
  • Marine & Offshore Engineering: Verifies the operational integrity of shipboard auxiliary generators, offshore platform power grids, and shipyard electrical infrastructure.
  • Utility & Substation Testing: Validates the capacity and reliability of industrial transformers, switchgear, and temporary power rentals.
  • Renewable Energy Integration: Load tests wind turbine generators and commercial solar (PV) inverters to ensure output stability before connection to the main grid.

 

 

High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps 0

High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps 1

 

High-Precision Resistive Load Bank 500KW 400V 50/60HZ Portable Design Adjustable Steps 2

 

 

Contact Details
Qingdao Kingway Industry Co., Ltd.

Contact Person: Mr. Bruce Jia

Tel: +8618653247836

Fax: 86-532-55718566

Send your inquiry directly to us (0 / 3000)