Product Details:
|
| Portability: | Portable Or Stationary | Application: | Generator Test |
|---|---|---|---|
| Control Power: | 380 VAC 50Hz | Load Capacity: | Varies (e.g., 10kW To 2000kW) |
| Rated Volage: | 400V | Color: | Customized |
| Heat Dispersion: | Air Cooling |
Our high-efficiency intelligent load banks are engineered to provide reliable, comprehensive performance testing and validation for demanding industrial power applications. By utilizing advanced resistive and inductive load control technology, our systems deliver optimized load simulation across diverse power sources, including diesel/gas generator sets, UPS systems, and micro-grids, ensuring maximum operational stability and system safety.
From factory acceptance testing (FAT) to on-site distributed power station commissioning, Kingway load testing systems integrate precision PLC steps, robust cooling architectures, and intelligent remote-monitoring software. Every unit is custom-calibrated to match specific voltage and power factor requirements ($0.8$ to $1.0$), significantly reducing the risk of power failure and wet-stacking while maximizing the long-term reliability of your energy assets.
| Feature | Detailed Configuration |
|---|---|
| Rating voltage/frequency | 400V, 3 phase 4 wire 50Hz |
| Max Load Power |
Apparent Power: 3500KVA Resistive Load: 2800KW Inductive Load: 2100KVAR |
| Load Resolution |
Resistive Load: 22 steps 1KW,2KW,2KW,5KW,10KW,10KW,20KW,50KW,100KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW, 200KW, 200KW, Inductive Load: 19 steps 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR,200KVAR,200KVAR,200KVAR,200KVAR |
| Power Factor | 0.8(lag) |
| Load Tolerance (each step) | ±5% |
| Load Tolerance (overall) | ±3% |
| Fan &Control Voltage | External AC 3 phase 4 line, 380V/50Hz |
| Wire Connection |
Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar |
| Communication Interface | RS485,RS232 |
| Insulation | F |
| Max Protection Grade | IP54 |
| Duty Cycle | Continuous |
| Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
| Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
| Internal Lighting | Adequate internal lighting will be provided |
| Transportation | Hoisting, there are lifting lug in top of casing |
| Color | Grey RAL7035 or as required |
| Dimensions | 6058mm×2350mm×2591mm(L×W×H) |
| Operating Environment Parameter | |
| Workplace | Outdoor |
| Ambient Temperature | -10℃~+50℃ |
| Relative Humidity | ≤95% |
| Atmospheric Pressure | 86~106kPa |
| Brands of Main Components | |
| Contactor | Schneider |
| Fuse | Miro |
| Alloy Resistor | KINGWAY |
| Data Processing Software | KINGWAY |
Precision Load Calibration: Advanced PLC multi-step control with precise resistive and inductive stepping to perfectly simulate real-world power factor conditions.
Thermal Dynamics Integration: Heavy-duty forced-air cooling systems with optimized airflow channels and high-temperature resistant alloy elements to extend equipment service life.
High Asset Protection: Accurate capacity and transient response validation prevents generator wet-stacking and grid failures, ensuring high ROI by securing your critical power infrastructure.
Full-Lifecycle Support: Comprehensive spare parts availability, intelligent remote-monitoring compatibility, and global technical diagnostic services.
Critical Infrastructure & Data Centers: Routine maintenance, sudden load-rejection testing, and capacity verification for backup UPS systems and standby diesel generators.
Marine & Shipyards: Full-load performance testing and factory acceptance testing (FAT) for shipboard power systems, marine thrusters, and offshore drilling platforms.
Energy & Utilities: Commissioning and periodic testing of distributed power stations, high-voltage substations, and renewable energy micro-grids (including Biogas and Natural Gas generator sets).
Q1: How do I choose the correct generator for my gas source?
A: Gas composition and pressure are critical. Please provide a gas analysis report (including H2S content), and our engineering team will suggest the optimal model.
Q2: Can the generator operate in extreme temperatures?
A: Yes, we provide custom cooling systems, including specialized radiators or heat exchangers, for operational environments ranging from -40°C to +50°C.
Q3: How often is maintenance required?
A: Maintenance cycles depend on gas quality. We provide a tailored maintenance schedule and digital monitoring tools to track performance and predict service intervals.