Product Details:
Place of Origin: China
Brand Name: Kingway
Certification: CE,ISO,ROHS
Model Number: KW71NHCSW-1/2A
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Packaging Details: Wooden Carton, PE Film
Delivery Time: 20 Working Days
Payment Terms: L/C, T/T, Western Union, D/P
Supply Ability: 300 Sets Per Year

Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner

Description
Product: Gas Heat Pump ( GHP )Cooling And Heating Air Conditioner Brand Name: Kingway
Place Of Origin: Shandong, China Certification: CE, ISO, ROHS
Color: Customized Warranty: 12 Months/ 1000 Working Hours
Delivery Time: 20 Working Days Fuel: Natural Gas ( NG)

Gas Heat Pump ( GHP )Cooling and Heating Air Conditioner

 

What is a gas heat pump air conditioner?
The gas heat pump air conditioner is an air conditioning unit that drives the compressor through a gas engine and circulates the gas heat pump for cooling or heating.


The difference between the gas heat pump air unit and the air source heat pump air conditioner is: the gas V heat pump air conditioner uses the TN city gas as the energy source: the air source heat pump air conditioner is driven by the built-in motor of the compressor, driven by the gas engine, and uses the gas as the energy source: the work uses electricity as the energy source .Self-developed GHP special gas engine.

 

Model KW40NHCSW-1/1A KW65NHCSW-1/2A KW71NHCSW-1/2A KW120NHSW-1/2A
Power supply 1N~220V 50Hz 1N~220V 50Hz 1N~220V 50Hz 1N~220V 50Hz

 

Performance

Nominal cooling capacity(KW) 40 65 71 -
Refrigeration condition heat recovery (KW) 23 37 40 -
Heating Capacity Nominal Capacity (KW) 45 73 80 120
Low Temperature (KW) 45 73 80 120
Gas consumption (low calorific value) Gas type Natural gas Natural gas Natural gas Natural gas
Nominal cooling (KW) 33.7 54.8 59.9 -
Nominal heating (KW) 33.9 55.1 60.2 65
Electrical Characteristics Refrigeration Running current (A) 4.68 7.60 8.30 -
Power consumption (KW) 0.95 1.54 1.68 -
Heating Running current (A) 4.39 7.14 7.80 12
Power consumption (KW) 0.88 1.44 1.57 2.1
Water flow Refrigeration (M3/h) 6.88 11.18 12.21 -
Heating (M3/h) 6.88 11.18 12.21 20.64
Domestic hot water (M3/h) 3.88 6.30 6.88 -
Compressor Type Vortex *1 Vortex *2 Vortex *2 Vortex *2
Displacement 86.2 86.2 86.2 86.2
Lubricant grade (Cm3/rev) FVC68D FVC68D FVC68D FVC68D
Refrigerator oil charge (L) 2*1 2*2 2*2 2*2
Crankshaft heating belt (W) 40*1 40*2 40*2 40*2

 

Engine

 

Range of rotation (RPM) 1000~2300 1000~2300 1000~2300 1000~2300
Displacement (cc) 2300 2300 2300 2300
Engine oil grade 5W-40 5W-40 5W-40 5W-40
Lubricating oil charge (L) 23 45 45 45
Start method DC Electric Start DC Electric Start DC Electric Start DC Electric Start
Engine cooling water Pump power (W) 152 252 252 252
Charge (L) 20 32 32 32
Concentration, freezing temperature 50V/V%~ -35°C 50V/V%~ -35°C 50V/V%~ -35°C 50V/V%~ -35°C
Refrigerant (R410A charge) Kg 11 10*2 10.5*2 10.5*2
Dimensions High (mm) 2296 2296 2296 2296
Width (mm) 1006 1006 1006 1006
Long (mm) 1436 2006 2006 2006
Weight (Kg) 600 9000 1000 1000
Maximum water resistance (Kpa) 50 50 50 50
Piping interface Air conditioning water pipe DN40 flange DN50 flange DN50 flange DN50 flange
Domestic hot water pipe G1-1/4” inner screw G1-1/4” inner screw G1-1/4” inner screw G1-1/4” inner screw
Gas piping (mm) Rc1/2” Rc3/4” Rc3/4” Rc3/4”
Running noise dB (A) 60 61 62 62
Fan Air supply form Axial Fan*1 Axial Fan*2 Axial Fan*2 Axial Fan*2
Rated air volume M3/h 1500 25000 27000 27000

 

Remark:

1. Refrigeration: The outdoor temperature is 35°C, and the outlet water temperature is 7°C. When the outlet water temperature is lower than 5°C during operation, antifreeze must be used as the refrigerant water.

2. The amount of heat recovery under refrigeration conditions: the outlet water temperature is 45°C. (Please note that this function is required when ordering)

3. Heating (nominal): outdoor temperature 7/6°C, outlet water temperature 45°C; heating (low temperature): outdoor temperature 2/1°C, outlet water temperature 45°C.

4. The type of gas is natural gas, and the pressure is low pressure. (Maximum pressure: 2.5kpa; Standard pressure: 2.0kpa; Minimum pressure 1.0kpa)

5. Actual gas consumption (Nm3/h) = gas consumption (kW) X3.6/35.4 (MJ/Nm3)

6. If the product is updated, the data is subject to change without prior notice.